Mulvaney S, Grech V. Haemolysis after Amplatzer
device closure of ventricular septal defect. Images Paediatr Cardiol 2007;32:4-5
|
| Embolization, Therapeutic, Instrumentation | Heart Catheterization/Instrumentation | Heart defects, congenital |
| Hemolysis |
Introduction
Congenital heart disease encompasses a variety of lesions that may
include communication/s between the left and the right side of the heart.
Such communications may cause volume overload in the short and medium term,
possibly resulting in heart failure, or irreversible complications in the
long term such as Eisenmenger’s syndrome. Previously, such defects (typically
atrial (ASD) and ventricular septal defects (VSD) and patent ductus arteriosus
(PDA)) were closed surgically. Over the last decade, a vast variety of
devices have been developed to close such defects through the transcatheter
route.
We report one patient who had self-limiting haemolysis after implantation of an Amplatzer perimembranous VSD device.
Patient
Our patient was born via normal vaginal delivery at 38 weeks gestation
after an uneventful preganacy. At the routine 6 week visit, she was noted
to be failing to thrive and a 3/6 systolic murmur was noted. Echocardiogram
done showed a large perimembranous VSD. Diuretics were commenced and she
throve. At 4 years of age, she was admitted to the paediatric surgical
ward with fever, abdominal pain and vomiting. Surgical exploration of the
abdomen under antibiotic cover was normal, as was an echocardiogram at
this time. Fever persisted and a repeat echocardiogram showed tricuspid
valve endocarditis with a large vegetation that eventually eroded part
of the valve resulting in significant regurgitation. The endocarditis was
treated with antibiotics and transcatheter closure of the VSD was done
successfully using a 14mm Amplatzer perimembranous VSD device at 5 years
of age. She was discharged on Aspirin for 6 months. One week after discharge,
she was readmitted due to jaundice and dark coloured urine. Haemoglobin
was 9.5g/dL, liver function tests were deranged (bilirubin 80umol/l; direct
bilirubin 12umol/l; gamma GT 80 U/l; ALT 58 U/l; Alkaline phosphatase 707
U/l, with urobilinogen in the urine. Viral studies, inclujding CMV, EBV,
Hepatitis A and B, were all negative. She was discharged home as after
two weeks as her jaundice cleared and her liver function tests improved.
One transfusion was needed.
Discussion
Device closure of septal defects may result in various complications.
These include endocarditis, device embolisation, cardiac rupture and arrhythmias.
Haemolysis has been documented after Amplatzer device closure of PDA,1 ASD,2 and VSD.3 The one reported case after VSD closure resulted in transient renal failure. 3 Hemolysis has also been associated with the use of Amplatzer devices to close paravalvar mitral valve leaks after mitral valve replacement.4
Conservative treatment is usually sufficient but reintervention of some form may occasionally be necessary, such as intradevice coil deployment in order to completely eliminate any degree of residual left to right shunting.5